IMPORTANCE OF ROENTGEN TUBE ANGLES IN CINEFLUOROSCOPIC INVESTIGATION OF MECHANICAL PROSTHESES
https://doi.org/10.15829/1560-4071-2014-1-ENG-23-26
Abstract
Aim. We planned a cinefluoroscopy (CF) study to mark the ideal opening and closing tube angles for mitral and aortic positioned mechanical valves. Our hypothesis was that if we find an intensity zone where the valves were optimally seen, then starting the CF examination from that tube position would shorten the examination duration
Material and methods. Between January 2010 and August 2011, 192 consecutive patients (mean age 51,86±12,80 years; 101 women and 91 male) with mitral (n=135; monoleaflet: 37; bileaflet: 98) and aortic (n=87; monoleaflet:19; bileaflet: 68) and tricuspid (n=3; all bileaflet) prostheses were enrolled into the study. Cinefluoroscopy was performed with Philips Radiologic System. For each type and location of mechanical prostheses optimal opening-closing angles obtained and marked on x-y axis graphic. Furthermore, we investigated whether there is an intensity zone quadrant.
Results. Among patients with prosthetic bileaflet mitral valve in supine position optimal images were obtained: 34 (58,6%) patients were in RAO-Cranial, 12 (20,7%) were in left anterior oblique (LAO) cranial, 7 (12,1%) were in RAO caudal and 5 (8,6%) were in LAO caudal angles. Among patients with prosthetic bileaflet aortic valves in supine position shown: 27 (50%) patients were in LAO-cranial, 10 (18,5%) were in RAO- cranial, 9 (16,7%) were in LAO-caudal and 8 (14,8%) patients were in RAO-caudal angles.
Conclusion. According to our results it seems logical to start mitral position CF assessment by RAO-Cranial angles quadrant and for aortic position by LAO-Cranial angles quadrant to decrease time and lower radiation exposure.
About the Authors
Uğur CoşkunMD, Istanbul University Institute of Cardiology, Department of Cardiology, Cardiologist, Instructor, Haseki Street, Haseki, Aksaray/Fatih 34350, Istanbul/Turkey, Tel: +90 212 459 20 00, Fax: +90 212 459 20 69
Barış Ökçün
Murat Başkurt
Kadriye Kılıçkesmez
Cem Bostan
Ahmet Yıldız
Alev Arat
Tevfik Gürmen
Mehmet Serdar Küçükoğlu
References
1. Rizzoli G, Guglielmi C, Toscano G, et al. Reoperations for acute prosthetic thrombosis and pannus: an assessment of rates, relationship and risk. Eur J Cardiothorac Surg 1999;16:74–80.
2. Teshima H, Hayashida N, Yano H, et al. Obstruction of St. Jude Medical valves in the aortic position: histology and immunohistochemistry of pannus. J Thorac Cardiovasc Surg 2003;126:401–7.
3. Aoyagi S, Nishimi Y, Kawano H, et al. Obstruction of St. Jude Medical valves in the aortic position: significance of a combination of cineradiography and echocardiography. J Thorac Cardiovasc Surg 2000;120:142–7.
4. Barbetseas J, Nagueh SF, Pitsavos C, et al. Differentiating thrombus from pannus formation in obstructed mechanical prosthetic valves: an evaluation of clinical, transthoracic and transesophageal echocardiographic parameters. J Am Coll Cardiol 1998;32:1410–7.
5. Montorsi P, De Bernardi F, Muratori M, et al. Role of cine-fluoroscopy, trans-thoracic and trans-esophageal echocardiography in patients with suspected prosthetic heart valve thrombosis. Am J Cardiol 2000;85:58–64.
6. Aoyagi S, Arinaga K, Fukunaga S, et al. Leaflet movement of the ATS valve in the aortic position: unique behaviour observed in 19-mm valves. Ann Thorac Surg 2006;82:853–7.
7. Ozkan M, Kaymaz C, Kirma C, et al. Intravenous thrombolytic treatment of mechanical prosthetic valve thrombosis: a study using serial transesophageal echocardiography. J Am Coll Cardiol. 2000;35:1881–9.
8. Koca V, Bozat T, Sarikamis C, et al. The use of transesophageal echocardiography guidance of thrombolytic therapy in prosthetic mitral valve thrombosis. J Heart Valv Dis. 2000;9:374–8.
9. Montorsi P, Cavoretto D, Alimento M, et al. Prosthetic mitral valve thrombosis: can fluoroscopy predict the efficacy of thrombolytic treatment? Circulation 2003; 108 [suppl 1]:1179–84.
10. Muratori M, Montorsi P, Teruzzi G, et al. Feasibility and diagnostic accuracy of quantitative assessment of mechanical prostheses leaflet motion by transthoracic and transesophageal echocardiography in suspected prosthetic valve dysfunction. Am J Cardiol. 2006;97 (1):94–100.
11. Cianciulli TE, Lax JA, Beck MA, et al. Cinefluoroscopic assessment of mechanical disc prostheses: its value as a complementary method to echocardiography. J Heart Valve Dis. 2005;14 (5):664–73.
Review
For citations:
Coşkun U., Ökçün B., Başkurt M., Kılıçkesmez K., Bostan C., Yıldız A., Arat A., Gürmen T., Küçükoğlu M.S. IMPORTANCE OF ROENTGEN TUBE ANGLES IN CINEFLUOROSCOPIC INVESTIGATION OF MECHANICAL PROSTHESES. Russian Journal of Cardiology. 2014;(1-ENG):23-26. https://doi.org/10.15829/1560-4071-2014-1-ENG-23-26