THE CASE OF SUCCESSFUL APPLICATION OF EMBOLIZING SYSTEM IN DISTAL PERFORATION OF CORONARY ARTERY
https://doi.org/10.15829/1560-4071-2015-12-126-128
Abstract
About the Authors
A. Yu. KrasnovRussian Federation
Stavropol
O. S. Belokon
Russian Federation
Stavropol
I. V. Fayans
Russian Federation
Stavropol
O. I. Boeva
Russian Federation
Stavropol
References
1. Al-Lamee R, Ielasi A, Latib A, et al. Incidence, predictors, management, immediate and long-term outcomes following grade III coronary perforation. JACC Cardiovasc Interv 2011; 4(1): 87-95.
2. Pershad A, Yarkoni A, Biglari D. Management of distal coronary perforations. J Invasive Cardiol 2008; 20(6): 187-91.
3. Yonemitsu T, Kawai N, Sato M, et al. Evaluation of transcatheter arterial embolization with gelatin sponge particles, microcoils, and n-butyl cyanoacrylate for acute arterial bleeding in a coagulopathic condition. J of Vasc and Intervent Radiol 2009; 20(9): 1176-87.
4. Goel PK, Syal SK. A unique and unexplained ricochet leak post PCI successfully treated with intra-coronary glue. IHJ 2014; 66(1): 122-6.
5. Pollak JS, White RI. Basic Study of a mixture of n-butyl cyanoacrylate, ethanol, and lipiodol as a new embolic material. J of Vasc and Intervent Radiol 2012; 23(11): 1516-21.
Review